利用模拟开关降低继电器的功耗,analog switch lowers relay power consumption
abstract: design idea outlining a method to use an analog switch and discrete components to reduce the power dissipated in relay actuation.
relays are often used as electrically controlled switches. unlike transistors, their switch contacts are electrically isolated from the control input. on the other hand, the power dissipation in a relay coil may be unattractive for battery-operated applications. you can lower this dissipation by adding an analog switch that allows the relay to operate at a lower voltage (figure 1).
figure 1. analog switch lowers relay power dissipation.
power consumed by the relay coil equals v²/rcoil. the circuit lowers this dissipation (after actuation) by applying less than the normal operating voltage of 5v. note that the voltage required to turn a relay on (pick-up voltage) is greater than that required to keep it on (dropout voltage). the relay shown has a 3.5v pick-up voltage and a 1.5v dropout voltage, yet the circuit allows it to operate from an intermediate supply voltage of 2.5v. table 1 compares the relay's power dissipation with fixed operating voltages across it, and with the figure 1 circuit in place.
table 1. power dissipated by relay
voltage
current
total power dissipation
5v (normal operating voltage)
90ma
450mw
3.5v (pick-up voltage)
63ma
221mw
2.5v (circuit of figure 1)
45ma
112mw
when you close sw1, current flows in the relay coil, and c1 and c2 begin to charge. the relay remains inactive because the supply voltage is less than its pick-up voltage. the rc time constants are such that c1 charges almost completely before the voltage across c2 reaches the logic threshold of the analog switch. when c2 reaches that threshold, the analog switch connects c1 in series with the 2.5v supply and relay coil. this action turns on the relay by boosting the voltage across its coil to 5v (twice the supply voltage). as c1 discharges through the coil, the coil voltage drops back to 2.5v minus the drop across d1, but the relay remains on because that voltage is above the relay's dropout voltage (1.5v).
component values for this circuit depend on the relay characteristics and the supply voltage. the value of r1, which protects the analog switch from the initial current surge through c1, should be sufficiently small to allow c1 to charge rapidly, but large enough to prevent the surge current from exceeding the peak current specified for the analog switch. u1's peak current is 400ma, and the peak surge current is ipeak = (vin vd1)/(r1 + ron), where ron is the on-resistance of the analog switch (typically 1.2ω). the value of c1 depends on the relay characteristics and on the difference between vin and the relay's pick-up voltage. relays that need more turn-on energy require larger c1 values.
the values for r2 and c2 are selected to allow c1 to charge almost completely before c2's voltage reaches the logic threshold of the analog switch. in this case, the time constant c2r2 is about seven times c1(r1 + ron). larger c2r2 values increase the delay between switch closure and relay activation.
a similar version of this article appeared in the december 20, 2001 issue of edn magazine.
短信删除了如何恢复?这招真的超管用
中微爱芯电源产品线介绍
单片机用一个I/O采集多个按键信号
HTC技术过硬,但为何还是在手机市场败了?
直流电源和地线连接电容的作用
利用模拟开关降低继电器的功耗,Analog Switch L
国庆档最强阵容《攀登者》携手国货品牌素士致敬攀登者
常用网络ip地址有哪些
FTTH技术对比及光纤接入技术应用策略
伊顿为商用车电气系统设计的DC-DC转换器
台积电赴美建厂背后有何深意?
5G时代到底那些行业非常吃香
家庭电路组成
小米武汉总部正式开园 从签约挂牌到建成使用仅两年时间
百度在北京发布小度智能音箱
瑞萨电子成功开发出第三代32位RX微控制器MCU,大幅度提升了稳定性
高性能电源保护电路
盘点全球十大著名黑客:苹果前CEO乔布斯上榜
电机保护控制器的主要功能、作用和特点
东芝推出检测电子设备温升的简单解决方案Thermoflagger™